DBK44 2-Channel 5B Signal-Conditioning Card
Overview ….. 1
Hardware Setup ….. 2
Power Considerations ….. 2
Card Configuration ….. 3
5B Module Connection ….. 3
Terminal Block Connection ….. 4
P1 Connection ….. 4
CE Compliance ….. 5
DaqBook/100 Series & /200 Series and DaqBoard [ISA type] Configuration …… 5
DaqBook/2000 Series and DaqBoard/2000 Series Configuration …… 6
Software Setup ….. 6
mx+b Values for 5B Modules ….. 7
DBK44 – Specifications ….. 7
Reference Notes:
o Chapter 2 includes pinouts for P1, P2, P3, and P4. Refer to pinouts applicable to your
system, as needed.
o In regard to calculating system power requirements, refer to DBK Basics located near
the front of this manual.
Reference Note:
Users of the DBK44 signal-conditioning card may be interested in the DBK207 and DBK207/CJC,
Carrier Boards for 5B Compatible Analog I/O Modules. Each DBK207 and DBK207/CJC board
includes a 100-pin P4 connector for DaqBoard/2000 Series and /2000c Series compatibility, two P1
connectors for analog expansion, a power connection terminal, and 16 signal terminal blocks. In
addition, the DBK207/CJC board includes CJC (Cold Junction Compensation) for thermocouple
applications. DBK207 and DBK207/CJC can be mounted in Nema-type panels.
Overview
The 2-channel DBK44 allows LogBook or Daq device systems to use any combination of 5B signal-
conditioning modules. 5B modules can accommodate a variety of signals (low-level thermocouple signals
to strain-gage signals, etc). Configuration options are flexible. You can select the type of signal attached
to each channel. One LogBook or Daq device can support up to 128 DBK44 cards, providing up to 256
isolated, analog input channels.
DBK Option Cards and Modules 877095 DBK44, pg. 1
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Overview

DBK44 2-Channel 5B Signal-Conditioning Card Overview ….. 1 Hardware Setup ….. 2 Power Considerations ….. 2 Card Configuration ….. 3 5B Module C

Page 2 - Hardware Setup

The LogBook or Daq device scans the DBK44’s channels at the same 10 µs/channel rate as other DBKs (256 scans in 2.56 ms in a full system). Each use

Page 3 - 5B Module Connection

Card Configuration Up to 128 DBK44s may connect to a LogBook or a Daq device system. Since this is a daisy-chain interface, each module must appear u

Page 4 - P1 Connection

When installing current input modules (SC-5B32 series), be sure to install the current-sense resistor (SC-AC-1362 shipped with the SC-5B32) in the r

Page 5 - CE Compliance

Note: A series of interface cables are available to connect up to 128 DBK44s. You can also use a DBK41 10-slot expansion chassis. DBK44 can be conn

Page 6 - Software Setup

DaqBook/2000 Series and DaqBoard/2000 Series Configuration No jumper configurations are required for these 2000 series devices. Software Setup Refere

Page 7 - 877095 DBK44, pg. 7

DBK Option Cards and Modules 877095 DBK44, pg. 7 mx+b Values for 5B Modules The mx+b calculations for most 5B modules are included within LogView s

Page 8 - DBK44 – Specifications

DBK44, pg. 8 877095 DBK Option Cards and Modules DBK44 – Specifications Name/Function: 2-Channel 5B Signal Conditioning Card Module Capacity: 2 “i