CB-7013, CB-7033 Users Manual
2.2 #**
Description: Synchronized Sampling
Syntax: #**[CHK](cr)
# A delimiter character.
** Synchronized sampling command.
Response: No response
Example:
Command: #** No response
Send synchronized sampling command.
Command: $014 Receive: >011+025.123
First read, get status=1
Command: $014 Receive: >010+025.123
Second read, get status=0
Related Command:
Sec. 2.8 $AA4
Note: The command is for CB-7013/13D only.