Measurement-computing CB-COM-7012 User Manual

Browse online or download User Manual for Hardware Measurement-computing CB-COM-7012. Measurement Computing CB-COM-7012 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
CB-7012, CB-7014, CB-7017 Users Manual
Copyright Sept., 2000 All rights are reserved.
CB-7012/12D/12F/12FD,
CB-7014D,
CB-7017/17F
Users Manual
Page view 0
1 2 3 4 5 6 ... 71 72

Summary of Contents

Page 1 - User’s Manual

1CB-7012, CB-7014, CB-7017 User’s ManualCopyright Sept., 2000 All rights are reserved.CB-7012/12D/12F/12FD,CB-7014D,CB-7017/17FUser’s Manual

Page 2 - Table of Contents

10CB-7012, CB-7014, CB-7017 User’s ManualCB-7012F/CB-7012FDAnalog InputInput Channel:1Input Type:mV, V, mA (with external125 ohms resistor)Fast Mode S

Page 3

11CB-7012, CB-7014, CB-7017 User’s ManualCB-7017Analog InputInput Channel:8 differential or 6 differen-tial and 2 single-ended byjumper selection.Anal

Page 4 - HM CB COM 7012 & 17.p65

12CB-7012, CB-7014, CB-7017 User’s Manual1.4 Functional Block Diagrams

Page 5 - 1. Introduction

13CB-7012, CB-7014, CB-7017 User’s Manual

Page 6 - 1.2 Pin Assignments

14CB-7012, CB-7014, CB-7017 User’s Manual1.5 ConnectionsCB-7012/12D/12F/12FDAnalog Input Wire ConnectionCB-7014D Analog Input WireConnectionCB-7012/12

Page 7

15CB-7012, CB-7014, CB-7017 User’s ManualCB-7017/17F Analog InputChannel 0 to 5 Wire ConnectionCB-7017/17F Analog InputChannel 6 and 7 Wire Connec-tio

Page 8

16CB-7012, CB-7014, CB-7017 User’s Manual1.6 Quick StartRefer to “CB-7000 Bus Converter User Manual” and“Getting Started” for more details.1.7 Default

Page 9 - 1.3 Specifications

17CB-7012, CB-7014, CB-7017 User’s Manual1.9 CalibrationDon’t Perform Calibration Until You Understand Procedure.Calibration requirements for CB-7012/

Page 10

18CB-7012, CB-7014, CB-7017 User’s Manual1.10 Configuration TablesConfiguration Table for CB-7012/12F/12D/12FD/14D/17/17F:Baud rate Setting (CC)Analog

Page 11

19CB-7012, CB-7014, CB-7017 User’s ManualepyTedoCegnaRtupnItamroFataD.S.F+oreZ.S.F-80V01+ot01-tinUreenignE000.01+000.00+000.01-RSFfo%00.001+00.000+00.

Page 12 - 1.4 Functional Block Diagrams

2CB-7012, CB-7014, CB-7017 User’s ManualTable of Contents1. Introduction...51.1 More Information ...

Page 13

20CB-7012, CB-7014, CB-7017 User’s Manual2. CommandsCommand Format: (Delimiter)(Address)(Command)[CHK](cr)Response Format: (Delimiter)(Address)(Data)[

Page 14 - 1.5 Connections

21CB-7012, CB-7014, CB-7017 User’s ManualsteSdnammoCretnuoCtnevEdnamralA,tuptuO/tupnIlatigiDdnammoCesnopseRnoitpircseDnoitceSIDAA@IIOOSAA!dnaO/Ilatigi

Page 15

22CB-7012, CB-7014, CB-7017 User’s ManualsteSdnammoCdetaleRgodhctaWtsoHdnammoCesnopseRnoitpircseD noitceS**~esnopseRoNKOtsoH 63.2.ceS0AA~SSAA!sutatSel

Page 16 - 1.8 Jumper Setting

23CB-7012, CB-7014, CB-7017 User’s Manual2.1 %AANNTTCCFFDescription: Set Module ConfigurationSyntax: %AANNTTCCFF[CHK](cr)% a Delimiter characterAA Add

Page 17 - 1.9 Calibration

24CB-7012, CB-7014, CB-7017 User’s ManualRelated Command:Sec. 2.7 $AA2Related Topics:Sec. 1.10, Configuration Tables; Sec. 3.1, INIT* pin Operation

Page 18 - 1.10 Configuration Tables

25CB-7012, CB-7014, CB-7017 User’s Manual2.2 #**Description: Synchronized SamplingNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: #**[

Page 19

26CB-7012, CB-7014, CB-7017 User’s Manual2.3 #AADescription: Read Analog InputSyntax: #AA[CHK](cr)# Delimiter characterAA Address of module (00 to FF)

Page 20 - 2. Commands

27CB-7012, CB-7014, CB-7017 User’s Manual2.4 #AANDescription: Read Analog Input from channel NNote: This command is for CB-7017/17F only.Syntax: #AAN[

Page 21

28CB-7012, CB-7014, CB-7017 User’s Manual2.5 $AA0Description: Perform Span CalibrationSyntax: $AA0[CHK](cr)$ Delimiter characterAA Address of module t

Page 22

29CB-7012, CB-7014, CB-7017 User’s Manual2.6 $AA1Description: Perform Zero CalibrationSyntax: $AA1[CHK](cr)$ Delimiter characterAA Address of module t

Page 23 - 2.1 %AANNTTCCFF

3CB-7012, CB-7014, CB-7017 User’s Manual2.11 $AA8 ...342.12 $AA8V ...

Page 24 - Related Topics:

30CB-7012, CB-7014, CB-7017 User’s Manual2.7 $AA2Description: Read ConfigurationSyntax: $AA2[CHK](cr)$ Delimiter characterAA Address of module (00 to

Page 25

31CB-7012, CB-7014, CB-7017 User’s Manual2.8 $AA4Description: Read Synchronized DataSyntax: $AA4[CHK](cr)$ Delimiter characterAA Address of module (00

Page 26

32CB-7012, CB-7014, CB-7017 User’s Manual2.9 $AA5VVDescription: Set Channel EnableNote: This command is for CB-7017/17F only.Syntax: $AA5VV[CHK](cr)$

Page 27 - 2.4 #AAN

33CB-7012, CB-7014, CB-7017 User’s Manual2.10 $AA6Description: Read Channel StatusNote: The command is for CB-7017/17F only.Syntax: $AA6[CHK](cr)$ Del

Page 28 - 2.5 $AA0

34CB-7012, CB-7014, CB-7017 User’s Manual2.11 $AA8Description: Read LED ConfigurationNote: The command is for CB-7012D/12FD/14D only.Syntax: $AA8[CHK]

Page 29 - 2.6 $AA1

35CB-7012, CB-7014, CB-7017 User’s Manual2.12 $AA8VDescription: Set LED ConfigurationNote: The command is for CB-7012D/12FD/14D only.Syntax: $AA8V[CHK

Page 30 - 2.7 $AA2

36CB-7012, CB-7014, CB-7017 User’s Manual2.13 $AA9(Data)Description: Set LED DataNote: This command is for CB-7012D/12FD/14D only.Syntax: $AA9(Data)[C

Page 31 - 2.8 $AA4

37CB-7012, CB-7014, CB-7017 User’s Manual2.14 $AAADescription: Read eight channel of dataNote: The command is for CB-7017/17F only.Syntax: $AAA[CHK](c

Page 32 - 2.9 $AA5VV

38CB-7012, CB-7014, CB-7017 User’s Manual2.15 $AAFDescription: Read Firmware VersionSyntax: $AAF[CHK](cr)$ Delimiter characterAA Address of module (00

Page 33 - 2.10 $AA6

39CB-7012, CB-7014, CB-7017 User’s Manual2.16 $AAMDescription: Read Module NameSyntax: $AAM[CHK](cr)$ Delimiter characterAA Address of module (00 to F

Page 34 - 2.11 $AA8

4CB-7012, CB-7014, CB-7017 User’s Manual2.35 $AAAV ...582.36 ~** ...

Page 35 - 2.12 $AA8V

40CB-7012, CB-7014, CB-7017 User’s Manual2.17 ~AAO(Data)Description: Module to set NameSyntax: ~AAO(Data)[CHK](cr)~ Delimiter characterAA Address of m

Page 36 - 2.13 $AA9(Data)

41CB-7012, CB-7014, CB-7017 User’s Manual2.18 ~AAEVDescription: Enable/Disable CalibrationSyntax: ~AAEV[CHK](cr)~ Delimiter characterAA Address of mod

Page 37 - 2.14 $AAA

42CB-7012, CB-7014, CB-7017 User’s Manual2.19 @AADIDescription: Read Digital I/O and Alarm StatusNote: This command is for CB-7012/12D/12F/12FD/14D on

Page 38 - 2.15 $AAF

43CB-7012, CB-7014, CB-7017 User’s Manual2.20 @AADO(Data)Description: Set Digital OutputNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax

Page 39 - 2.16 $AAM

44CB-7012, CB-7014, CB-7017 User’s Manual2.21 @AAEATDescription: Enable AlarmNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: @AAEAT[CH

Page 40

45CB-7012, CB-7014, CB-7017 User’s Manual2.22 @AAHI(Data)Description: Set High AlarmNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: @A

Page 41 - 2.18 ~AAEV

46CB-7012, CB-7014, CB-7017 User’s Manual2.23 @AALO(Data)Description: Set Low AlarmNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: @AA

Page 42 - 2.19 @AADI

47CB-7012, CB-7014, CB-7017 User’s Manual2.24 @AADADescription: Disable AlarmNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: @AADA[CHK

Page 43 - 2.20 @AADO(Data)

48CB-7012, CB-7014, CB-7017 User’s Manual2.25 @AACADescription: Clear Latch AlarmNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: @AACA

Page 44 - 2.21 @AAEAT

49CB-7012, CB-7014, CB-7017 User’s Manual2.26 @AARHDescription: Read High AlarmNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: @AARH[C

Page 45 - 2.22 @AAHI(Data)

5CB-7012, CB-7014, CB-7017 User’s Manual1. IntroductionCB-7000 is a family of network data acquisition and controlmodules. They provide analog-to-digi

Page 46 - 2.23 @AALO(Data)

50CB-7012, CB-7014, CB-7017 User’s Manual2.27 @AARLDescription: Read Low AlarmNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: @AARL[CH

Page 47 - 2.24 @AADA

51CB-7012, CB-7014, CB-7017 User’s Manual2.28 @AAREDescription: Read Event CounterNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: @AAR

Page 48 - 2.25 @AACA

52CB-7012, CB-7014, CB-7017 User’s Manual2.29 @AACEDescription: Clear Event CounterNote: This command is for CB-7012/12D/12F/12FD/14D only.Syntax: @AA

Page 49 - 2.26 @AARH

53CB-7012, CB-7014, CB-7017 User’s Manual2.30 $AA3Description: Read Source Low/High Values for Linear MappingNote: This command is for CB-7014D only.S

Page 50 - 2.27 @AARL

54CB-7012, CB-7014, CB-7017 User’s Manual2.31 $AA5Description: Read Target Low/High Values for Linear MappingNote: This command is for CB-7014D only.S

Page 51 - 2.28 @AARE

55CB-7012, CB-7014, CB-7017 User’s Manual2.32 $AA6(SL)(SH)Description: Set Source Low/High Values for Linear Mapping.Note: This command is for CB-7014

Page 52 - 2.29 @AACE

56CB-7012, CB-7014, CB-7017 User’s Manual2.33 $AA7(TL)(TH)Description: Set Target Low/High Values for Linear MappingNote: The command is for CB-7014D

Page 53 - 2.30 $AA3

57CB-7012, CB-7014, CB-7017 User’s Manual2.34 $AAADescription: Set Linear Mapping StatusNote: The command is for CB-7014D only.Syntax: $AAA[CHK](cr)$

Page 54 - 2.31 $AA5

58CB-7012, CB-7014, CB-7017 User’s Manual2.35 $AAAVDescription: Enable/Disable Linear MappingNote: This command is for CB-7014D only.Syntax: $AAAV[CHK

Page 55 - 2.32 $AA6(SL)(SH)

59CB-7012, CB-7014, CB-7017 User’s Manual2.36 ~**Description: Host OK.Host sends this command to tell all modules “Host is OK”. (Actu-ally resets the

Page 56 - 2.33 $AA7(TL)(TH)

6CB-7012, CB-7014, CB-7017 User’s Manual1.2 Pin Assignments

Page 57 - 2.34 $AAA

60CB-7012, CB-7014, CB-7017 User’s Manual2.37 ~AA0Description: Read Module StatusSyntax: ~AA0[CHK](cr)~ Delimiter characterAA Address of module to rea

Page 58 - 2.35 $AAAV

61CB-7012, CB-7014, CB-7017 User’s Manual2.38 ~AA1Description: Reset Module StatusSyntax: ~AA1[CHK](cr)~ Delimiter characterAA Address of module to se

Page 59 - 2.36 ~**

62CB-7012, CB-7014, CB-7017 User’s Manual2.39 ~AA2Description: Read Host Watchdog Timeout IntervalSyntax: ~AA2[CHK](cr)~ Delimiter characterAA Address

Page 60 - 2.37 ~AA0

63CB-7012, CB-7014, CB-7017 User’s Manual2.40 ~AA3EVVDescription: Set Host Watchdog Timeout IntervalSyntax: ~AA3EVV[CHK](cr)~ Delimiter characterAA Ad

Page 61 - 2.38 ~AA1

64CB-7012, CB-7014, CB-7017 User’s Manual2.41 ~AA4Description: Read PowerOn Value and Safe ValueNote: This command is for CB-7012/12D/12F/12FD/14D onl

Page 62 - 2.39 ~AA2

65CB-7012, CB-7014, CB-7017 User’s Manual2.42 ~AA5PPSSDescription: Set PowerOn Value and Safe ValueNote: This command is for CB-7012/12D/12F/12FD/14D

Page 63 - 2.40 ~AA3EVV

66CB-7012, CB-7014, CB-7017 User’s Manual3. Application Notes3.1 INIT* Pin OperationEach CB-7000 module has a build-in EEPROM to storeconfiguration in

Page 64 - 2.41 ~AA4

67CB-7012, CB-7014, CB-7017 User’s Manual3.3 Dual Watchdog OperationDual Watchdog = Module Watchdog + Host WatchdogThe Module Watchdog is a hardware r

Page 65 - 2.42 ~AA5PPSS

68CB-7012, CB-7014, CB-7017 User’s Manualignore the digital output command @AADO(Data).3.6 High/Low AlarmSome analog input modules, such as the CB-701

Page 66 - 3. Application Notes

69CB-7012, CB-7014, CB-7017 User’s Manualamplified.Two-wire transmitters typically output a 4 to 20 mA cur-rent output signal. One wire is for power

Page 67 - 3.5 Digital Output

7CB-7012, CB-7014, CB-7017 User’s Manual

Page 68 - 3.7 Transmitter

70CB-7012, CB-7014, CB-7017 User’s Manual1. Set the CB-7014D to read ±20 mA type.Command: %01010D0600 Receive: !01(Ref. Sec. 2.1 %AANNTTCCFF)2. Set th

Page 69 - 3.8 Linear Mapping

71CB-7012, CB-7014, CB-7017 User’s ManualEC Declaration of ConformityWe, Measurement Computing Corporation, declare under soleresponsibility that the

Page 70

Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: [email protected] ww

Page 71

8CB-7012, CB-7014, CB-7017 User’s Manual

Page 72

9CB-7012, CB-7014, CB-7017 User’s Manual1.3 SpecificationsCB-7012/CB-7012DAnalog InputInput Channels: 1Input Type:mV, V, mA (with external125 ohms res

Related models: CB-COM-7017