3.1.2 Differential Inputs
Differential inputs measure the voltage between two distinct input signals. Within a certain range (referred to as the common mode
range), the measurement is almost independent of signal source to CIO-DAS08-PGA ground variations. A differential input is also
much more immune to EMI than a single-ended one. Most EMI noise induced in one lead is also induced in the other, the input
only measures the difference between the two leads, and the EMI common to both is ignored. This effect is a major reason there is
twisted pair wire as the twisting assures that both wires are subject to virtually identical external influence. Figure 3-2 below
shows a typical differential input configuration.
Figure 3-2. Differential Input Configuration