There are fewer ranges available for the CIO-DAS08-PGL. Gains of 2, 4 & 8 are often called binary gains. These ranges are not
available on the MetraByte DAS-8PGA.
011066+
0.6258
004044+
1.254
010022+
2.52
000000+
5.01
000188+
10.00.5
R0R1R2R3HEXDECRANGE VGAIN
CONTROL CODESBI-POLAR
CIO-DAS08-PGL
1100770 to 1.258
1010550 to 2.54
1100330 to 5.02
1000110 to10.01
R0R1R2R3HEXDECRANGE VGAIN
CONTROL CODESUNI-POLAR
CIO-DAS08-PGL
0111E14+0.018
0011C12+
0.054
0101A10+
0.52
000000+
5.01
000188+
10.00.5
R0R1R2R3HEXDECRANGE VGAIN
CONTROL CODESBI-POLAR
CIO-DAS08-PGM
1111F150 to 0.018
1010D130 to 0.14
1101B110 to 1.02
1001990 to10.01
R0R1R2R3HEXDECRANGE VGAIN
CONTROL CODESUNI-POLAR
CIO-DAS08-PGM
To set the input range of the CIO-DAS08-PGx board, select the desired range from the table and write the code in decimal or
hexadecimal to base address + 3. Here is an example in BASIC:
100 OUT &H303, 8 'Set gain = 0.5 (±10V range)
The range of the analog inputs is now set to ±10V or 2.44mV per bit (10/4096).